An accepted manuscript published in the American Journal of Roentgenology (AJR) guides optimization of clinical protocols when implementing ultra-high-resolution photon-counting detector (UHR PCD) CT of the lungs, providing insights on the association of reconstruction kernel and slice thickness with image quality.
Evaluating the impact of the kernel and slice thickness on image quality of UHR PCD CT of the lungs using a 1024×1024 matrix, “the sharpest evaluated kernel, BI64, was the optimal kernel, consistent with the current clinical-reference technique,” wrote corresponding author Helmut Prosch from the department of biomedical imaging and image-guided therapy at the Medical University of Vienna in Austria.
Within the research, 29 patients (17 women, 12 men; median age, 56 years) underwent non-contrast chest CT using a first-generation PCD scanner (NAEOTOM Alpha, Siemens Healthineers, Forchheim, Germany) from February 15 to March 15, 2022. All acquisitions used UHR mode. Nine image sets were reconstructed for all combinations of three sharp kernels (BI56, BI60, BI64) and three slice thicknesses (0.2, 0.4, 1.0 mm). Three radiologists independently reviewed reconstructions for measures of visualization of pulmonary anatomic structures and pathologies using clinical reference BI641.0-mm.
Ultimately, when performing PCD CT of the lungs in UHR mode, reconstruction using BI64 kernel and 0.4-mm slice thickness was the only assessed reconstruction to yield improved bronchial division identification and bronchial wall and pulmonary fissure sharpness, without loss in pulmonary vessel sharpness or conspicuity of nodules or other pathologies.
In comparison, a 0.2-mm slice thickness—the thinnest reconstruction possible—was “associated with decreased visualization of various anatomic and pathologic findings,” the researchers noted.
more recommended stories
Tumor Removal Could Get Easy with Advanced Imaging
The distinction between cancerous tumors and.
Novel Immunotherapy To Treat Complex Tumors
A symposium was presented at the.
First Wearable Health Sensor To Track Muscle Atrophy
The first wearable sensor created by.
Promising Prostate Cancer Treatment Is Here
Research by Neeraj Agarwal, MD, called.
Paralysis Due To ALS Could Be Delayed with DNA Treatment
A protein called TDP-43 is lost.
Females With Unexplained Infertility Are More Prone To Cancer, Heart Disease
According to research from the Medical.
Equine-Facilitated Therapy to Help Low Back Pain Patients
A recent study from the University.
Improvement in Pediatric Tuberculosis Diagnosis
One of the top causes of.
Improvement in Kids’ Blood Sugar with Artificial Pancreas
A recent study shows that children.
Meatless Proteins May Trigger Soy & Peanut Allergy
Many people who want to consume.
Leave a Comment